quote:

Oversizing is as bad as undersizing.


This is important! If the unit is oversized, it will not run long enough to pull the humidity out of the air. Then you will still feel hot because you can't sweat.

Some utility companies will audit the house for free and propose a size.

Add a little bit to that to compensate for aging of unit.

The size estimates by the HVAC companies tend to be rule of thumb and do not take into account the heavy insulation you have!


LINK

LINK
Posted by TygerDurden
Member since Sep 2009
1975 posts
Posted on 9/21/15 at 7:02 am to
I just had to replace two AC units in my home because they were not sized properly. A coils continually had moisture on them and they eventually developed corrosion and I lost my freon. These units were only 7 years old. Very important what had been stated in previous posts about insulation, types of windows and how much shade your new house will have. I highly suggest a 18 to 20 seer variable speed unit. Will cost more on the the upfront but you should have noticble lower electric bills. For your upstairs a 15 seer std unit should work fine since you will not spend much time there. put your AC money where the family will be most.
Posted by rodnreel
South La.
Member since Apr 2011
1559 posts
Posted on 9/21/15 at 7:26 am to
I recommend getting a dvd by Doug Rye an architect in arkansas. He shows how to build an energy efficient house.

When I built I used most of his recommendations. I doubled my sq. ft. and cut my utility bills in half.

his comments on insulation and ac units will be of interest to you.
This post was edited on 9/21/15 at 7:28 am
Posted by Libertariantiger
Member since Nov 2012
981 posts
Posted on 9/21/15 at 7:28 am to
The upstairs solution is not complex and will cost about the same as a mini split system. It takes a computer board to open the baffles to the two areas. Some people do these zones for each room in their house. That is a little much, but for an upstairs with different heat loads, it works great.
Posted by OleBallCoach
Member since Nov 2007
1089 posts
Posted on 9/21/15 at 7:42 am to
(no message)
This post was edited on 11/17/15 at 9:18 pm
Posted by madmaxvol
Infinity + 1 Posts
Member since Oct 2011
22489 posts
Posted on 9/21/15 at 8:02 am to
quote:

Not sure about the downstairs tonnage, but the upstairs mini-split is the only way to go. Just be sure to get some kind of wall mount for to hold the remote.


Couldn't agree more. For that size space (300 sq ft), it is the best route to follow. I've heard very good things about the Mitsubishi and Fujitsu units.

Posted by cajunangelle
Member since Oct 2012
171153 posts
Posted on 9/21/15 at 8:16 am to
quote:

5 ton downstairs - ductless mini split upstairs.
Posted by Rev1897
NOLA
Member since Dec 2008
782 posts
Posted on 9/21/15 at 8:31 am to
We are building 3900ft2 living area and we're doing a 4.5 ton downstairs (2700ft2) and 2.0 up (1200 ft2).

Our HVAC did a manual J. Because we are doing spray foam all over he said 6.5 tons was the right amount.

Agree with other posters on over sizing. Particularly with my foam house, everything I have read says over sizing can be an issue. Not sure about with BATT.
Posted by WeeWee
Member since Aug 2012
46010 posts
Posted on 9/21/15 at 8:59 am to
quote:

Couldn't agree more. For that size space (300 sq ft), it is the best route to follow. I've heard very good things about the Mitsubishi and Fujitsu units.


I have 2 Fijitsu units. I can't complain
Posted by madmaxvol
Infinity + 1 Posts
Member since Oct 2011
22489 posts
Posted on 9/21/15 at 9:04 am to
quote:

Couldn't agree more. For that size space (300 sq ft), it is the best route to follow. I've heard very good things about the Mitsubishi and Fujitsu units.


quote:

I have 2 Fijitsu units. I can't complain


I've heard some good things about Daikin units...but I don't know enough about them to recommend one, yet.
Posted by Ziggy
Member since Oct 2007
22146 posts
Posted on 9/21/15 at 10:12 am to
quote:

I've heard some good things about Daikin units...

Daikin makes a great unit. I would pick them over Mitsubishi, LG, or Fujitsu.
Posted by TigerRob20
Baton Rouge
Member since Nov 2008
3733 posts
Posted on 9/21/15 at 10:28 am to
What should be a normal humidity level if the HVAC is properly sized?

Posted by soccerfüt
Location: A Series of Tubes
Member since May 2013
76218 posts
Posted on 9/21/15 at 10:31 am to
Can't


stop



looking


at



your


avatar....
Posted by TigerstuckinMS
Member since Nov 2005
33687 posts
Posted on 9/21/15 at 10:51 am to
quote:

What should be a normal humidity level if the HVAC is properly sized?


Below about 30% RH, the vast majority of people will find it uncomfortably dry. Above 65% or so, you start running the risk of microbial growth in the HVAC system.

So, It's typically somewhere in the range of 30-60% or so, but is highly subjective and dependent on temperature, activity levels, air velocities, radiant heat sources, whether TigerRob20's avatar is in the room with you, etc., etc.
This post was edited on 9/21/15 at 10:56 am
Posted by Ziggy
Member since Oct 2007
22146 posts
Posted on 9/21/15 at 10:54 am to
quote:

whether TigerRob20's avatar is in the room with you, etc., etc.

Posted by N2cars
Member since Feb 2008
40407 posts
Posted on 9/21/15 at 12:53 pm to
quote:

We are building 3900ft2 living area and we're doing a 4.5 ton downstairs (2700ft2) and 2.0 up (1200 ft2). Our HVAC did a manual J. Because we are doing spray foam all over he said 6.5 tons was the right amount. Agree with other posters on over sizing. Particularly with my foam house, everything I have read says over sizing can be an issue. Not sure about with BATT.


Can still happen, but obviously not as likely.

I love foam. Quiet house, cheap electricity bills, all good. The ROI takes a bit, but worth it.


Posted by Rev1897
NOLA
Member since Dec 2008
782 posts
Posted on 9/22/15 at 10:16 am to
quote:

I love foam. Quiet house, cheap electricity bills, all good. The ROI takes a bit, but worth it.



Yea, the ROI is the drawback. Also, I've heard to run some pvc through the walls to make sure you can run cords later.
Posted by N2cars
Member since Feb 2008
40407 posts
Posted on 9/22/15 at 10:24 am to
I left a chase from 1 to 2, but I would've done that anyway.

Running cables down a wall is PITA, bit the fireblock is the issue.

Foam drills pretty easy.
Posted by EA6B
TX
Member since Dec 2012
14754 posts
Posted on 9/22/15 at 11:14 am to
quote:

Yea, the ROI is the drawback. Also, I've heard to run some pvc through the walls to make sure you can run cords later.


Where there was stuff like network, cable TV , home theater wiring or something that may need to be revised possibly years down the road I put in a plastic conduit from the attic down to the outlet box. Has already paid off several times for things I didn't think of up front. I know everyone will be yelling its stupid with today's wireless devices, but I like wire.
first pageprev pagePage 2 of 3Next pagelast page

Back to top
logoFollow TigerDroppings for LSU Football News
Follow us on X, Facebook and Instagram to get the latest updates on LSU Football and Recruiting.

FacebookXInstagram