Page 1
Page 1
Started By
Message

Tankless water heater issues

Posted on 8/27/26 at 7:13 am
Posted by tigerrage08
Houma,LA
Member since Feb 2008
634 posts
Posted on 8/27/26 at 7:13 am
I have a state tankless water heater (gas) that will provide hot water for several minutes, then cool off in the middle of a shower. At times it will also only get lukewarm, as opposed to get hot, and at times it will not get hot at all. Does anyone have experience with this and have any idea how to troubleshoot this? This behavior also goes on with the sink faucets as well, so it is not a just a shower issue. The water heater is about 6 years old.
This post was edited on 8/27/26 at 7:17 am
Posted by UptownJoeBrown
Baton Rouge
Member since Jul 2024
12029 posts
Posted on 8/27/26 at 9:07 am to
Sometimes old school is the best.
Posted by LOL
Member since Jun 2015
908 posts
Posted on 8/27/26 at 9:49 am to
Look up "Cold Water Sandwich" and see if that is it.
Posted by way_south
Member since Jul 2017
972 posts
Posted on 8/27/26 at 12:16 pm to
Are you on a well? We had this issue and had to turn up pressure to get enough flow. On a particular low flow shower we had to run the hot water in the sink during a shower to keep hot water.
Posted by tigerrage08
Houma,LA
Member since Feb 2008
634 posts
Posted on 8/27/26 at 12:28 pm to
No well, city water.
Posted by Shepherd
Member since Nov 2009
3102 posts
Posted on 8/27/26 at 12:53 pm to
I was told they had to be de-scaled yearly.. that factored in to not transitioning to that style when I replaced mine.
Posted by USEyourCURDS
Member since Apr 2016
12985 posts
Posted on 8/27/26 at 1:06 pm to
A lot of people don't but you're also supposed to flush the regular tank type as well.
Posted by RIPMachoMan
Member since Jun 2011
9430 posts
Posted on 8/27/26 at 3:19 pm to
Make sure you have the right gas line size feeding it.
Posted by TheBoo
South to Louisiana
Member since Aug 2012
5569 posts
Posted on 8/27/26 at 7:14 pm to
Actually yes, yes I do. I have a 3 year old state GTS510 outdoor unit. Had a similar problem a couple months ago. Mine would vent really loud and couldn’t handle low flow (slightly warm showers) without losing flame, and would randomly shut off in the middle of a bath or shower.

You have to call customer support and they will transfer you to technical support and open a case. If it’s within warranty they will help line that up. If not, they will troubleshoot it with you to determine what the issue could be and send you whatever parts to change.

I called and she walked through troubleshooting with me. Sent me a text with a link to a video call app where she used an on screen arrow to point to things she needed me to check. It was pretty legit. She was perplexed by what it could be so she put me on hold to consult her team. They came back with low flow valve on the valve and manifold assembly, so they sent me one.

That ended up being exactly right. The low flow valve wasn’t working properly, so anytime flow would be low enough to only engage the low flow valve it would lose flame. I changed it and has worked perfectly ever since.
Posted by Scarface
West Monroe
Member since Jan 2005
87 posts
Posted on 8/27/26 at 8:10 pm to
I had this same issue. After doing some research, my shower head put out more than 2 GPM. The on demand hot water system couldn't keep up with that flowrate. I replaced the shower head to a 1.8 GPM (recommendations are for a GPM < 2 GPM). This solved my problem and I haven't had any issues since. I hope this helps and solves your problem as well.
Posted by AtticusOSullivan
Member since Mar 2016
3090 posts
Posted on 8/27/26 at 8:34 pm to
Had a tankless fail after 3 years. Im all tank now and its glorious.
Posted by Maillard
BTR
Member since Jul 2021
459 posts
Posted on 8/27/26 at 9:09 pm to
how small of a a water heater you buy that it can't feed 2 gallons per minute. they even make such an animal
Posted by Will Cover
Davidson, NC
Member since Mar 2007
40395 posts
Posted on 8/27/26 at 10:02 pm to
quote:

I had this same issue. After doing some research, my shower head put out more than 2 GPM. The on demand hot water system couldn't keep up with that flowrate. I replaced the shower head to a 1.8 GPM (recommendations are for a GPM < 2 GPM).




I have an 11.1 GPM tankless, and I have to turn every faucet on in the house, along with all three tubs and a shower, and then, and only then, it can't keep up to produce enough hot water for all faucets, tubs, and shower.
Posted by bluewing
south
Member since Jun 2013
175 posts
Posted on 8/28/26 at 12:21 pm to
i had this problem only in my shower. took the restrictor out the shower head and never had a problem since
Posted by DevilDogTiger
RTWFY!
Member since Nov 2007
6647 posts
Posted on 8/28/26 at 10:13 pm to
Had the same problem. You need to descale your tank. ( super easy ). Then change the check valve ( super easy and $4 for the new part)
YouTube told me everything when the plumber couldn’t figure it out
Posted by Scarface
West Monroe
Member since Jan 2005
87 posts
Posted on 8/29/26 at 12:04 am to
It was already installed in the house when I bought it. The master shower was the only one that would go cold, never get hot, or work fine sometimes. All other faucets worked great. When I changed the shower head, it corrected the issue. I know it sounds strange, but that's what fixed it.
Posted by cgrand
HAMMOND
Member since Oct 2009
50893 posts
Posted on 8/29/26 at 9:47 am to
you’ve gotten good advice it’s almost always a flow issue. The other thing you can try is to turn the temp down some
first pageprev pagePage 1 of 1Next pagelast page