Posted on 9/27/22 at 8:41 pm
Posted by bapple
Capital City
Member since Oct 2010
11878 posts
Posted on 9/27/22 at 8:41 pm
Was considering redoing all the insulation in my attic this winter and thought it might be better to find exactly where all the heat is getting into my rooms. The picture is a knee wall in my living room that is apparently completely uninsulated. I imagine I'll find a lot more trouble spots with more examining.

I figured for $300 this imager is something I could use for many other tasks. The breaker panel will be the next place examined to see which breakers are getting a bit too hot and may need replacing.

If you have any other ideas of what to do with this gadget, shoot me some suggestions.

LINK



Posted by meeple
Carcassonne
Member since May 2011
9346 posts
Posted on 9/27/22 at 8:50 pm to
Be cool for hide and go seek with the kids.

Does it work like the Predator’s IR?

Posted by Schmelly
Member since Jan 2014
14448 posts
Posted on 9/27/22 at 8:51 pm to
Def will know if your is haunted as well
Posted by bapple
Capital City
Member since Oct 2010
11878 posts
Posted on 9/27/22 at 9:05 pm to
quote:

Be cool for hide and go seek with the kids.



Hadn't even thought of this but solid suggestion.

quote:

Def will know if your is haunted as well


I'll just not look in the master bedroom so I can sleep peacefully in that room at least.
Posted by wickowick
Head of Island
Member since Dec 2006
45799 posts
Posted on 9/27/22 at 9:07 pm to
Awesome for checking for water leaks also. Any one buying a home should have an inspection with a thermal
Posted by TygerDurden
Member since Sep 2009
1847 posts
Posted on 9/27/22 at 9:52 pm to
The wife would be invisible on this thing.
Posted by j1897
Member since Nov 2011
3560 posts
Posted on 9/27/22 at 10:23 pm to
LINK


70 cheaper, been around for years.
Posted by belowmebama
Member since Jul 2008
7304 posts
Posted on 9/27/22 at 10:58 pm to
It appears possible that there gizmo may detect a little critter in a wall.
Posted by Clames
Member since Oct 2010
16541 posts
Posted on 9/28/22 at 1:10 am to
That's adorable... I bought a Flir E4 for about $1000 6 years ago. Immediately downloaded a file to reflash it to the same spec as the E8 version. There's several threads about this hack on eevblog.com

Don't know if yours will have the resolution and sensitivity but mine will see small drafts around doors, windows, base, crown moulding, any kind of moisture leak, pick out electrical wiring under load. Can even see the paw prints left by a dog or cat.
Posted by THRILLHO
Metry, LA
Member since Apr 2006
49489 posts
Posted on 9/28/22 at 1:18 am to
quote:

The breaker panel will be the next place examined to see which breakers are getting a bit too hot and may need replacing.


Breaker/conductor temperature will be influenced by current draw and length of time that the current is drawn. Hotter breakers are unlikely to be an indication of upcoming failure. The National Electrical Code even calls for derating (oversizing) conductors/breakers for loads that are expected to be energized for 3+ hours due to the heat created.

If you replace your hottest breaker at 6PM today, and your behavior/the weather don't change significantly, then your new breaker is likely to still be your hottest at 6PM tomorrow.




Posted by JumpingTheShark
America
Member since Nov 2012
22891 posts
Posted on 9/28/22 at 6:56 am to
quote:

That's adorable... I bought a Flir E4 for about $1000 6 years ago. Immediately downloaded a file to reflash it to the same spec as the E8 version. There's several threads about this hack on eevblog.com Don't know if yours will have the resolution and sensitivity but mine will see small drafts around doors, windows, base, crown moulding, any kind of moisture leak, pick out electrical wiring under load. Can even see the paw prints left by a dog or cat.


Sheesh….Captain Inferiority Complex over here with the one up
Posted by Meauxjeaux
98836 posts including my alters
Member since Jun 2005
39887 posts
Posted on 9/28/22 at 7:34 am to
quote:

Be cool for hide and go seek with the kids.

Hadn't even thought of this but solid suggestion.


So wrong and so right from a daddy perspective.
Posted by commode
North Shore
Member since Dec 2012
1141 posts
Posted on 9/28/22 at 8:35 am to
Do you think it would work at night to track wounded deer?
Posted by REB BEER
Laffy Yet
Member since Dec 2010
16172 posts
Posted on 9/28/22 at 8:57 am to
quote:

Do you think it would work at night to track wounded deer?


We tried before in some really thick cover and it didn't pick up much better than just using a bright light.
Posted by bapple
Capital City
Member since Oct 2010
11878 posts
Posted on 9/28/22 at 9:15 pm to
quote:

Breaker/conductor temperature will be influenced by current draw and length of time that the current is drawn. Hotter breakers are unlikely to be an indication of upcoming failure. The National Electrical Code even calls for derating (oversizing) conductors/breakers for loads that are expected to be energized for 3+ hours due to the heat created.


Well sure, the conductor will get to a stable temperature from the current draw. If there is excess current draw causing thermal runaway the thermal portion of the breaker should trip from overload. But internal contact resistance can increase over time from arcing and corrosion buildup, right? I would imagine over the course of 30+ years under operation it may start to wear out. So if I have more heat buildup internally in the breaker than expected that might mean high contact resistance and more heat than expected under normal operation.

I may be overestimating this issue since I did field work with a NETA testing company where we were working mostly on 480V industrial switchgear and the occasional 4160V or 13.8kV equipment. Contact resistance can play a big part in those but maybe on a much smaller scale for 120V I have the images of those in my head that aren't reality . Definitely possible.

quote:

We tried before in some really thick cover and it didn't pick up much better than just using a bright light.


It's not high enough resolution or capable of distances for something like that. For small upclose jobs is where it is most useful, hence the lower price tag.
Posted by j4lsu
Pineville
Member since Aug 2006
2923 posts
Posted on 9/29/22 at 8:40 am to
quote:

Do you think it would work at night to track wounded deer?


quote:

We tried before in some really thick cover and it didn't pick up much better than just using a bright light.


quote:

It's not high enough resolution or capable of distances for something like that. For small upclose jobs is where it is most useful, hence the lower price tag.


do you (or anyone) have any suggestions for a thermal that would help in tracking wounded deer?
Posted by BayouBengal51
Forest Hill, Louisiana
Member since Nov 2006
6533 posts
Posted on 9/29/22 at 11:24 am to
Would be handy for some advanced engine troubleshooting. You could look at your heads and headers to see if you have a cold cylinder.

Also can help with diagnosing issues with catalytic converters.
This post was edited on 9/29/22 at 11:25 am
Posted by prestigeworldwide
Member since May 2018
295 posts
Posted on 9/29/22 at 12:12 pm to
quote:

70 cheaper, been around for years.


I use the Flir One Pro for my android.
Posted by Harlan County USA
Member since Sep 2021
537 posts
Posted on 9/29/22 at 7:06 pm to
quote:

I bought a Flir E4 for about $1000 6 years ago. Immediately downloaded a file to reflash it to the same spec as the E8 version. There's several threads about this hack on eevblog.com


I'm glad you posted this info...I have been using a Flir E4 to scan low slope roofs for moisture/leaks/overall condition. I have read about the "hack" to do what you described but I didn't know where to get that info. Would a new E4 permit the reflash to an E8. You'd think Flir would combat that somehow.
Posted by Dandaman
Louisiana
Member since May 2017
703 posts
Posted on 9/30/22 at 8:31 am to
I used one to inspect my AC ductwork to see where the leaks were.