Help repairing leak in copper drain line at tankless heater w/ propress fittings

Posted on 10/30/26 at 9:35 am
Posted by Randall Savauge
Member since Aug 2021
847 posts
Posted on 10/30/26 at 9:35 am
I noticed a wet spot on the brick outside of one of my tankless heaters. looks like i have a small leak in one of the propress fittings on the copper drain line. looking to diy the repair but there's no meat on the pipe for me to cut and install new fittings. how would one remove these type of fittings? going to be tight... leak is where the red circle is. it's dripping into the pan then that drips outside the housing and down my wall.



This post was edited on 10/30/26 at 9:36 am
Posted by baldona
Florida
Member since Feb 2016
24775 posts
Posted on 10/30/26 at 11:24 am to
There’s no solution that I know of but I’m not a plumber. You can probably use a dremel or hand saw to cut that pro press off but I don’t think a plumber would do that. A plumber is going to go back to the stub out where there’s copper available and re do the rest of it from there most likely.

You could shark bit all that for $50 or so most likely. I don’t love them but it’s an option depending on what the rest of your plumbing looks like.


Posted by AndyCBR
Baton Rouge, LA
Member since Nov 2012
8489 posts
Posted on 10/30/26 at 12:14 pm to
If it was me I would repipe it all in solder fittings back to the wall.

Not sure what went wrong here but it's why I am not a fan of propress in general. Yes, soldered fittings can be installed wrong and leak also. But I've always wondered what happens to the o-ring seal in the propress fittings decades later.

You can get a Mapp torch and the fittings, flux, solder, and sandpaper for not too much money.
Posted by Spankum
The Sip
Member since Jan 2007
64130 posts
Posted on 10/30/26 at 1:00 pm to
I would personally hire a plumber to rebuild the whole thing with soldered fittings. Too many compression and threaded fittings there for my taste!
This post was edited on 10/30/26 at 1:01 pm
Posted by rltiger
Metairie
Member since Oct 2004
2955 posts
Posted on 10/30/26 at 4:57 pm to
Here’s what I’d try first. Turn off water, remove connected hose. Clean/ steel wool around pipe, get a 1” rubber sleeve or smaller, cut down to fit where leak is, put on and hose clamp it tight. $7 home depot attempt.

Posted by White Bear
Section 8
Member since Jul 2014
17918 posts
Posted on 10/30/26 at 5:13 pm to
quote:

But I've always wondered what happens to the o-ring seal in the propress fittings decades later.
I’d reckon they’ll disintegrate
Posted by sledgehammer
SWLA
Member since Oct 2020
8245 posts
Posted on 10/30/26 at 6:16 pm to
I’ve seen a few blow out in a freeze. The plumber should’ve used sweat fittings since everything is butted together like that.
Posted by Napoleon
Kenna
Member since Dec 2007
76085 posts
Posted on 10/31/26 at 11:16 am to
Cut below the elbow and replace everything in that picture.
Though I prefer to use solder and a torch.
Posted by dillpickleLSU
Baton Rouge, LA
Member since Oct 2005
26649 posts
Posted on 10/31/26 at 11:18 am to
Where are you located? If in BR I can help you DIY. Homeimpbydl@gmail.com
Posted by Napoleon
Kenna
Member since Dec 2007
76085 posts
Posted on 10/31/26 at 11:18 am to
I feel solder is more reliable and easier to make repairs on down the line.
Even in fridges I still solder rather than Lokring (hvac propress)
Posted by LeftBR74
Houston
Member since Apr 2023
28 posts
Posted on 11/1/26 at 12:19 pm to
Question - is that a drain (unpressurized) line or the cold water inlet line (60 psi +/-)? Would make a difference in my mind as to the repair. If pressure, I would remove any nearby Pro Press fittings and replace with soldered. If unpressurized, try cleaning around the fitting until it shines and apply J-B Weld.

BTW - AI says Pro Press is a metal to metal seal with a O-ring secondary seal. Sounds like both failed.

Disclaimer - I am not a plumber. If a pressurized line, I would hire an expert.
Posted by 385 Tiger
Member since Jan 2009
318 posts
Posted on 11/2/26 at 3:27 pm to
I think this is the best and only reasonable answer. May need a union to properly tie into the water heater. Can't really tell from the picture
Posted by td1
Baton Rouge
Member since Oct 2015
3248 posts
Posted on 11/2/26 at 6:05 pm to
I’d say you are going to have to cut out all the fitting back to the stub and redo. As was already said, I’d go back with sweated fittings. At least you could have heated the bad one up and replaced it with sweated fittings. I have nothing against pro press, but that’s a tight space with a lot of connections to rip out if it happens again.
Posted by 385 Tiger
Member since Jan 2009
318 posts
Posted on 11/2/26 at 6:54 pm to
That's what I meant if I wasn't clear. I don't know much about pro press, but they have to have some sort of washer or seal. I don't know how you could sweat anything in without ruining the entire thing. This back to square one.
Posted by PaBon
UPT 17th W/D
Member since Sep 2014
2285 posts
Posted on 11/2/26 at 8:13 pm to
I agree with Tiger here.

I also know that all those butted fittings that are pressed are a no-no according to the specifications of the product.com. I’m not a plumber but do own a pro press.

I’d pex that whole thing out and call it a day.
Posted by 385 Tiger
Member since Jan 2009
318 posts
Posted on 11/3/26 at 7:25 am to
If it's outside, I don't think you can use pex because of the UV