Started By
Message

re: Man Killed After Being 'Sucked' Into MRI Machine

Posted on 1/29/18 at 6:28 pm to
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 1/29/18 at 6:28 pm to
It turns into gas once released.
Posted by kywildcatfanone
Wildcat Country!
Member since Oct 2012
141237 posts
Posted on 1/29/18 at 6:31 pm to
What did the MRI show?
Posted by Langland
Trumplandia
Member since Apr 2014
15382 posts
Posted on 1/29/18 at 6:31 pm to
quote:

It turns into gas once released.


"Maru's autopsy showed his cause of death to be toxic amounts of inhaled LIQUID oxygen, according to the Hindustan Times"
Posted by EA6B
TX
Member since Dec 2012
14754 posts
Posted on 1/29/18 at 6:40 pm to
I did research in MRI for many years, and worked for a couple of the major manufacturers of MRI systems.

There is a lot of questionable information in the article.

1. The vast majority of MRI systems use cryogenically cooled superconducting magnets, they are never "off" in normal operation.

2. It said the hospital worked to try to free the man severing his fingers, the magnets have a "quench" button that can be used to de-energize the magnet in less than a minute in a emergency situation like this. To recover a magnet after a emergency quench, it is possible someone made the very wrong decision to try freeing the man by other methods and avoid the expense.

3. I have never seen liquid oxygen in a portable container in a hospital, and there is no aspect of a MRI system that would employee liquid oxygen. Small cylinders of compressed oxygen are frequently brought into the MRI scan room with patients that require it. Because of a couple of accidents, almost all hospitals use aluminum oxygen cylinders that are safe to bring in the magnet room.

If you become trapped against the magnet by a ferrous object weighing more than a couple of pounds you are not going to be able to free yourself. A engineer working for GE, was carrying a module used by the system that contained a electric motor, they got too close to the magnet and were pinned against the magnet with the module on their chest, not being able to take a breath they died of asphyxiation.

As someone else posted the inverse square law is in play around the magnet, the difference between being able to retain control a ferrous object and having it snatched out of you hands can be only a couple of inches.
This post was edited on 1/29/18 at 6:43 pm
Posted by CHEDBALLZ
South Central LA
Member since Dec 2009
23354 posts
Posted on 1/29/18 at 6:41 pm to
Ive heard people who work around metal have to get an xray of their head to make sure no metal particles are in their eye before getting an MRI, any truth to that?
Posted by Pectus
Internet
Member since Apr 2010
67302 posts
Posted on 1/29/18 at 6:41 pm to
I think it's time to call the Mythbusters...
Posted by northLAgoomba
Grand Cane, LA
Member since Nov 2009
3979 posts
Posted on 1/29/18 at 6:52 pm to
This is some Final Destination shite.
Posted by BearsFan
Member since Mar 2016
1286 posts
Posted on 1/29/18 at 6:56 pm to
It is true that welders can have pieces of medal in there body. Wether or not you have ever been a welder is a question on an MRI form.
Posted by BearsFan
Member since Mar 2016
1286 posts
Posted on 1/29/18 at 6:57 pm to
Unfortunately this sort of stuff (although not usually to this extreme) has happened in many places. There is a Red quench button on the wall in MRI suites but if you hit that thing it is like 50 or 100k + to fix the magnet.
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 1/29/18 at 6:59 pm to
I don’t know how the liquid O2 would be prevented from instantly boiling upon exposure to the environment, so I’m going with my conclusion.
Posted by EA6B
TX
Member since Dec 2012
14754 posts
Posted on 1/29/18 at 6:59 pm to
quote:

Ive heard people who work around metal have to get an xray of their head to make sure no metal particles are in their eye before getting an MRI, any truth to that?


True
Posted by foshizzle
Washington DC metro
Member since Mar 2008
40599 posts
Posted on 1/29/18 at 7:01 pm to
quote:

I'm sure this wasn't a pleasant death


quote:

Maru inhaled a huge amount of oxygen due to which he fell unconscious


He was apparently out long before he died.
Posted by foshizzle
Washington DC metro
Member since Mar 2008
40599 posts
Posted on 1/29/18 at 7:03 pm to
quote:

And people on this board want Indian doctors to come here and practice


MRI techs are not physicians. In the US you get an Associates Degree at a radiology tech school and then work on getting certified.
Posted by Martini
Near Athens
Member since Mar 2005
49697 posts
Posted on 1/29/18 at 7:05 pm to
I was put into one last week, got to my waist, said nope and pulled out.

frick that and I’ve never had a phobia of any kind. Have to go use the upright one later this week.

After reading this might just keep the tumor for awhile.
Posted by Restomod
Member since Mar 2012
13493 posts
Posted on 1/29/18 at 7:06 pm to
ICU Bed



Wheel Chair




Floor Buffer



Posted by EA6B
TX
Member since Dec 2012
14754 posts
Posted on 1/29/18 at 7:07 pm to
quote:

Unfortunately this sort of stuff (although not usually to this extreme) has happened in many places. There is a Red quench button on the wall in MRI suites but if you hit that thing it is like 50 or 100k + to fix the magnet.


$50-100 grand if it can be recovered, there is a small chance of permanent damage, then it could be $500k-750K to replace the magnet.
Posted by redstick13
Lower Saxony
Member since Feb 2007
41386 posts
Posted on 1/29/18 at 7:09 pm to
that floor buffer.
Posted by EA6B
TX
Member since Dec 2012
14754 posts
Posted on 1/29/18 at 7:10 pm to
quote:

MRI techs are not physicians. In the US you get an Associates Degree at a radiology tech school and then work on getting certified.


The field is getting like what happened to RNs, the A.S. was all that was needed, but hospitals are now wanting a B.S. in Rad Tech, and that is what most of the kids going into that field are getting.
This post was edited on 1/29/18 at 7:11 pm
Posted by LEASTBAY
Member since Aug 2007
16682 posts
Posted on 1/29/18 at 7:30 pm to
I used to work in MRI. I have a BS. If you quench the magnet it can actually destroy the building. Look up some YouTube vids of it happening. That magnet is always on. Ain't no 100k fix either.
This post was edited on 1/29/18 at 7:32 pm
Posted by reggielendale
Member since Jan 2006
1103 posts
Posted on 1/29/18 at 7:33 pm to
Surely a securityvideo of this will be released. Hopefully.
first pageprev pagePage 2 of 3Next pagelast page

Back to top
logoFollow TigerDroppings for LSU Football News
Follow us on X, Facebook and Instagram to get the latest updates on LSU Football and Recruiting.

FacebookXInstagram