Camp baws... Help with a generator issue please

Posted on 6/15/19 at 1:47 pm
Posted by deuceiswild
South La
Member since Nov 2007
5232 posts
Posted on 6/15/19 at 1:47 pm
Does anyone know how to disable the CO Guard feature on a Briggs generator? We run this thing in a shed that’s outside of the camp. It’s a pain in the arse even with a fan ventilating the little shed.
Posted by Jack Daniel
Gold member
Member since Feb 2013
29686 posts
Posted on 6/15/19 at 2:00 pm to
You wanting to take a permanent nap, baw?
Posted by Mr Wonderful
Love City
Member since Oct 2015
1045 posts
Posted on 6/15/19 at 2:12 pm to
You could always just have electricity run to the shed. Problem solved.
Posted by keakar
Member since Jan 2017
30152 posts
Posted on 6/15/19 at 2:12 pm to
then just run the damn exhaust through the wall to outside and mount the muffler to it there

its just a 1" threaded pipe
This post was edited on 6/15/19 at 2:13 pm
Posted by tgrbaitn08
Member since Dec 2007
148031 posts
Posted on 6/15/19 at 2:13 pm to
quote:


then just run the damn exhaust through the wall to outside and mount the muffler to it there

its just a 1" threaded pipe


fricking millennials
Posted by TastyJibblets
North of I-10
Member since Jun 2018
681 posts
Posted on 6/15/19 at 2:58 pm to
Are you asking how to disable a switch or am I missing something?
Posted by Cracker
in a box
Member since Nov 2009
19317 posts
Posted on 6/15/19 at 4:04 pm to
Plumb the damn exhaust
Posted by deuceiswild
South La
Member since Nov 2007
5232 posts
Posted on 6/15/19 at 4:05 pm to
We don’t want to go through the wall if we don’t have to. I didn’t ask for other suggestions, i simply asked if anyone knows how to disable this feature.

For those of you crying about someone dying, for one, it’s in a shed that only the generator is kept in. And two, how the frick did you survive all these years without this sensor on your generator?!?!
Posted by DownshiftAndFloorIt
Here
Member since Jan 2011
72751 posts
Posted on 6/15/19 at 4:10 pm to
You should pipe the exhaust outside. The engine is breathing exhaust also, amazing that it even stays running.

But the switch is either normally opened or normally closed. Unplug it, if the alarm stays then jump the leads together.
Posted by deuceiswild
South La
Member since Nov 2007
5232 posts
Posted on 6/15/19 at 4:19 pm to
There’s a ventilation fan in the shed. Obviously it’s not quite big enough.

We didn’t write down the engine model before we left so i can’t download the wiring schematic without that number. Any idea precisely what mechanism the sensor uses to kill the engine? There are a few ways to do it. Plugging the sensor isn’t an option because a sensor malfunction will kill the engine as well. This is why i believe it might not be as simple as just cutting a wire. A jumper may be required but not certain where to connect the jumper.
Posted by DownshiftAndFloorIt
Here
Member since Jan 2011
72751 posts
Posted on 6/15/19 at 4:27 pm to
It likely breaks the key switch circuit, so it's probably just a normally closed switch. Odds are if you trace the wire that goes to the key switch you'll find the sensor. The oil level switch is on that circuit also, make sure you dont unhook that.