re: Clarksville Tennessee Area - GeneralLeeAwesome
Well I was stationed there from 2007 to 2018 when I retired. I actually just sold my house there. I was renting it out for the past few years. I love the area, if you’re an outdoorsman type there is so much to do. The bars close at 0200 now...
Posted on O-T Lounge
Jump to Post - View Topic - Replies (1)
re: Is it possible to get the smoke smell out of a house where the owner smoked for years? - GeneralLeeAwesome
[img]https://mk0aironeheatinad6mx.kinstacdn.com/wp-content/uploads/2020/07/airpurifier.jpg[/img]...
Posted on O-T Lounge
Jump to Post - View Topic - Replies (2)
re: Air conditioning issue - GeneralLeeAwesome
Yeah this was what I was saying. You should have a float switch coming from the evaporator coil. It will just pull out and if that drain line is clogged you’ll need to blow it out with some sort of forced air. The bobber on it works just like a toilet. When the water backs up in the coil drain pan i...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
I’m in St Charles but I’m willing to travel all over to work. I’m hustling now so I don’t have to work for anyone else in the next 3 years. dixonsairconditioning@gmail.com...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
I agree but it depends on how it was wired in. Is it wired in series with the condenser, is the tstat a 5 wire, does he have batteries in it. I wire mine to kill the condenser because I want refrigerant to stop flowing and creating condensate ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
I like being in the field. My goal is to run solo for myself. I still think the simplest fix on this is a partially clogged drain line and the float switch going on and off. Especially if it’s a single stage lower efficiency unit and he didn’t have any spring maintenance done on it. I see it eve...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
Could be just going out or a short in the wires there. My test is to just bypass them and see if the issue continues or not...
Posted on Home & Garden
Jump to Post - View Topic - Replies (0)
re: Air conditioning issue - GeneralLeeAwesome
Absolutely. I retired from the army and used my GI Bill to go to school for this and have been in the field now for 5 years. I’ve learned after numerous mistakes, I go through the entire system on every single call. ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
Low on refrigerant will do it IF there are pressure switches ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
You could also have a bad low or high pressure safety switch in the condenser. Though not all condensers have them...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
Not necessarily. ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (0)
re: Air conditioning issue - GeneralLeeAwesome
That would blow the fuse in the control board and the condenser wouldn’t kick on at all after the first time ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
Sure what area do you live in?...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
I mean who knows. I have a procedure that I do on every call. I go the the thermostat the, evaporator coil then the condenser. I check all components of the system every unit I look at. Not all service techs do that. ...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Air conditioning issue - GeneralLeeAwesome
Go into your attic and see if you have a float switch coming off the Evaporator Coil. Pull it out and check the drain line. It could be mostly clogged with a slow drain backing up on that float which will kill the condenser and the second the float drops back down it’ll kick on. Without a delay prog...
Posted on Home & Garden
Jump to Post - View Topic - Replies (1)
re: Texans thermostats raised remotely without their knowledge during “energy saving event” - GeneralLeeAwesome
Just pull the thermostat off the wall and bypass it by wiring R,Y,& G together. Now it may get cold in the house but it won’t shut off. ...
Posted on O-T Lounge
Jump to Post - View Topic - Replies (0)
re: Ya nodding ya head now Ayon? - GeneralLeeAwesome
I said in his first inning he was going to piss off our batters. Sure enough ...
Posted on Tiger Rant
Jump to Post - View Topic - Replies (2)
re: What's the going rate for A/C freon - GeneralLeeAwesome
R22 I charge $200 for the first 3#s total after that it’s $80 per pound. I can drop R421A as a drop in replacement for $50 a pound ...
Posted on O-T Lounge
Jump to Post - View Topic - Replies (0)
re: Question for combat veterans that actually watch war movies - GeneralLeeAwesome
That is the most realistic story yet...
Posted on O-T Lounge
Jump to Post - View Topic - Replies (0)