re: Can someone help decode this pump's specs for me?
Posted on 6/10/15 at 9:37 pm to Street Hawk
Posted on 6/10/15 at 9:37 pm to Street Hawk
sorry for all of the questions, but all of that goes into sizing of a pump...
what flowrate is necessary?...
what flowrate is necessary?...
Posted on 6/10/15 at 9:38 pm to PrivatePublic
quote:Easy-peasey.
My question is where are you going to find a 100 volt system to use this with?
You step down 110v to 100v.
European and Japanese electrical apparatus are not built to our specs. A converter is needed.
Here's a link to a cheap one:
LINK
This post was edited on 6/10/15 at 9:40 pm
Posted on 6/10/15 at 9:45 pm to Spankum
quote:
sorry for all of the questions, but all of that goes into sizing of a pump...
what flowrate is necessary?...
I don't know the flow rate. I just know that it needs to be able to provide a constant vacuum of 25 inHg. There will be a regulator that will turn it down to 18 inHg at the machine, but once in a while, if required, it could be turned all the way up to 25 inHg. I know that the size of the tubing will be 3/8", if that helps.
Posted on 6/10/15 at 9:56 pm to Street Hawk
Flow rate will only matter if you plan on having a leak or a specified recovery time.
Posted on 6/10/15 at 9:57 pm to Street Hawk
Seriously though, what is your application? I'm curious
Posted on 6/10/15 at 9:58 pm to Street Hawk
What is the application ?
Posted on 6/11/15 at 11:30 am to Clames
quote:
Might help if you had specified this is a dry vacuum pump. Ultimate pressure isn't a positive reference here, it's telling you it can draw down to 3.32kPa (atmosphere is 101.4 kPa) which is almost 29 in-Hg gauge or between 96% and 97% vacuum. So yeah, that pump would work.
You were right. Thanks dude.