Need a BR HVAC design specialist to diagnose and repair HVAC system

Posted on 7/20/23 at 8:11 am
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/20/23 at 8:11 am
My AC is just not keeping up with the heat. I have a 2500 sq ft single level home running 2 units.

The floors are all spray foamed. I get wildly varying vent temp readings across the house. One unit never stops and I cannot get below 73 degrees at night. It is nearly 80 degrees when I go to sleep.

I need someone that can come diagnose and make suggestions on fixing this problem. Thanks in advance for any recommendations for the person for this job.
Posted by LSUDad
Still on the move
Member since May 2004
61910 posts
Posted on 7/20/23 at 9:38 am to
Call Stephen with SEC A/C.

(225) 571-7774
Posted by redfish99
B.R.
Member since Aug 2007
18735 posts
Posted on 7/20/23 at 10:01 am to
Winters Air.
Posted by PenguinPubes
Frozen Tundra
Member since Jan 2018
11720 posts
Posted on 7/20/23 at 11:31 am to
That does sound a little extreme.. but keep in mind it’s literally 100 degrees every day this time of the year. It’s just fricking hot outside

My ac units run about 16-18 hours a day this month. It’s hot
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/20/23 at 12:14 pm to
quote:

but keep in mind it’s literally 100 degrees every day this time of the year. It’s just fricking hot outside


yes, I know.

quote:

It’s hot


Yes, I know.
Posted by Wasp
Off Highland rd.
Member since Sep 2012
1533 posts
Posted on 7/20/23 at 1:37 pm to
What temperature is the air coming out at from the closest vent to the unit?
Posted by gerald65
Moss Bluff, LA
Member since Jul 2020
710 posts
Posted on 7/20/23 at 3:00 pm to
Checking outlet vents is a good starting point. Also go outside and check the 2 freon lines on each A/C unit. The big one should be cold and the small one fairly hot. Also check that the fans are blowing out fairly warm [hot] air.

Make a mental note of how the 2 units compare on each of this things.

Also, when checking the outlet vents, be sure to see if both A/C units are blowing out the same amount of air.

If the A/C units have not had the coils cleaned this spring, this could be cause your problem. Also, have the air filters always been changed regularly?
Posted by gerald65
Moss Bluff, LA
Member since Jul 2020
710 posts
Posted on 7/20/23 at 3:07 pm to
Also, did both A/C units cool the house in the past or/and did your problem just start? Has anything changed that could effect how the A/C operates?
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/20/23 at 7:05 pm to
Coils are clean. New capacitors and fans in both units.

Lines are appropriate temps.

Vents closest to intake are coldest. 9° difference. 71° to 80° It’s not been this bad in the past.
Posted by sleepytime
Member since Feb 2014
3857 posts
Posted on 7/20/23 at 9:32 pm to
Call Kennedy Mechanical. LINK

I 100% guarantee he can figure your problem out quick and fix it the right way without upselling you on contracts or unnecessary BS. He has fixed the same issue on my house and about 5 other people that I know. I’m not related or anything, just a happy customer after using several supposedly reputable companies that couldn’t deliver.
Make sure the owner, John, comes out for the consult.
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/21/23 at 7:38 am to
quote:

He has fixed the same issue on my house and about 5 other people


what was the fix?
Posted by CrawDude
Baton Rouge
Member since Apr 2019
5692 posts
Posted on 7/21/23 at 10:01 am to
quote:

Vents closest to intake are coldest. 9° difference. 71° to 80° It’s not been this bad in the past.

You may have multiple issues with air flow, insulation, envelope leakage, etc. but a 9 F split between the return vent and closet air supply vent does sound to me more like a equipment/refrigerant issue - you should have something on the order of a 16 to 20 F temperature split. If it was strictly an reduced air flow issue but with properly working equipment, one might expect a higher temperature split between the return plenum and supply plenum or closet supply register.

If you use one of the techs recommended and get a good outcome, let us know - many, including myself, are looking for a good tech in the BR area with a good diagnostic skills.
This post was edited on 7/21/23 at 1:50 pm
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/21/23 at 10:56 am to
Yeah, I'm leaning toward low refrigerant. I got my old regular guy to call me back so we shall see...
Posted by gerald65
Moss Bluff, LA
Member since Jul 2020
710 posts
Posted on 7/21/23 at 11:20 am to
CrawDude

quote:

but a 9 F split between the return vent and closet air supply vent


I think he is saying..... The closet vent is 9 degrees cooler than the vent farthest away. And that is a big difference in vent outlet temperatures. I don't remember if he said if the air flow at all vents is about the same or is his "HOT" part of the house not getting good air flow.
Posted by sleepytime
Member since Feb 2014
3857 posts
Posted on 7/21/23 at 12:00 pm to
Replaced some of the duct work wasn’t sized correctly, added a drop or 2 and put diverters in the ducts to get the right amount of air flow to each room. Most AC guys do “rule of thumb” calculations when it comes to calculating the sizing of the unit, # of drops and sizing of the duct work. John has a much better understanding of how all that works and will get it right.
Posted by CrawDude
Baton Rouge
Member since Apr 2019
5692 posts
Posted on 7/21/23 at 2:07 pm to
quote:

I think he is saying..... The closet vent is 9 degrees cooler than the vent farthest away. And that is a big difference in vent outlet temperatures. I don't remember if he said if the air flow at all vents is about the same or is his "HOT" part of the house not getting good air flow.

Understood - then that would certainly suggest air flow, duct size, duct insulation, related issues, maybe in addition to some equipment issues.

Which does provide an opportunity to remind everyone that duct work and associated airflow is every bit as as important as the equipment sizing and operation in home comfort. One on the HVAC techs on the HVAC Talk Forum likes to state, the equipment just cools or heats the air, but the duct work is what really provides home comfort. All the components are equally important. Most the techs on that same forum state the the most common problem they see with homeowners with chronic home comfort issues is over sized equipment (tonnage) with undersized ductwork.
Posted by Motorboat
At the camp
Member since Oct 2007
23935 posts
Posted on 7/31/23 at 7:50 am to
So to update this, my regular guy came out and tweaked the fan motors. This helped but I am still unable to get down below 74 at night. When I went to bed at 9:30, it was 80.

So not a refrigerant or an outside unit issue. It appears to be more of a ductwork/insulation issue. Calling one of the recommended guys today.