Started By
Message

re: Generac Generator Sitting 5-6 Years With Old Gas — What Would You Do?

Posted on 8/20/26 at 7:21 am to
Posted by The Mick
Member since Oct 2010
45198 posts
Posted on 8/20/26 at 7:21 am to
1. Drain gas (or suction it out)
2. Replace carburetor ($30 amazon)
3. Add new non-ethanol gas
4. Fire it up
Posted by Loup
Ferriday
Member since Apr 2019
17712 posts
Posted on 8/20/26 at 10:52 am to
When I got my generac it had been sitting up with gas in it for about the same amount of time as yours. An old man had gotten it for Hurricane Gustav as a back up and had only run it ~10 hours. I had to replace the fuel lines, filter, spark plug, on/off switch, and do an oil change. I took the carb off and sprayed out all the lil holes and jets that I could get to without breaking it apart. It fired right up after that. I run it every 6 months or so, still fires right up.
Posted by Royalfishing
Member since Jul 2023
472 posts
Posted on 8/21/26 at 5:18 am to
In addition to all the fuel and fuel line suggestions, check for dirt dobber and rodents nests and remove.
Posted by Clames
Member since Oct 2010
19974 posts
Posted on 8/21/26 at 6:27 am to
quote:

. Drain tank. reconnect hose. refill with fresh gas. open valve and try to start.



Good way to send trash into the carburetor. Drain all the fuel from the tank & carburetor float bowl and inspect both for rust and debris. Want everything to be clean or it's going to be a frustrating time getting a generator to run well.
Posted by Napoleon
Kenna
Member since Dec 2007
74900 posts
Posted on 8/21/26 at 7:23 am to
Drain fuel.
Clean carb.