Posted on 11/13/26 at 5:47 pm
Posted on 11/13/26 at 5:47 pm
Had gas furnace my whole life. We have a freeze warning in North Georgia tonight and when I turned the heat on, the condenser outside kicked on. Is that normal?
Posted on 11/13/26 at 6:02 pm to VandyBoysWhistler
Yes. The outdoor coil in “heat mode” now becomes the evaporator coil absorbing heat from the outside air, transferring it via the refrigerant to the indoor coil, that now becomes the condenser coil, releasing that heat into the house.
Posted on 11/13/26 at 6:10 pm to CrawDude
Thanks for the info CrawDude. Anything else to know?
Posted on 11/13/26 at 7:10 pm to VandyBoysWhistler
quote:
Thanks for the info CrawDude. Anything else to know?
No, not really, but rest assured that heat pump technology has been around 50+ years and is reliable. Just a bit more complex than a split forced air AC with gas furnace but not by much.
Well one possible thing. Air temperature leaving the supply air grill from a gas furnace might be 105-115 F, whereas, air temperature from a heat pump will be a bit cooler, 95 F or so. So you might note a difference there if you sitting near a supply register, but your house air temperature will equalize to whatever your thermostat is set to.
This post was edited on 11/14/26 at 11:50 am
Posted on 11/13/26 at 8:10 pm to VandyBoysWhistler
Heat pumps work great. Depending on the unit, usually can do a 25-30degree differential from outside temp to inside temp.
If you encounter significantly lower temps than your heat pump can overcome, your unit should have back up electric heat strips to provide aux/emergency heating. Electric bill will suffer those times, but should be fairly rare they are needed.
If you encounter significantly lower temps than your heat pump can overcome, your unit should have back up electric heat strips to provide aux/emergency heating. Electric bill will suffer those times, but should be fairly rare they are needed.
Posted on 11/13/26 at 8:24 pm to VandyBoysWhistler
Be sure to”auxiliary heat” is enabled, so that it can kick in if your heat pump struggles.
“Emergency heat” should remain off.
“Emergency heat” should remain off.
Posted on 11/13/26 at 8:35 pm to VandyBoysWhistler
Posted on 11/13/26 at 8:43 pm to White Bear
Man, that’s an old commercial!
Posted on 11/14/26 at 7:06 am to Spankum
Heat pumps struggle below 32 degrees.
Posted on 11/14/26 at 8:12 am to Allthatfades
Modern ones will work down into the negatives.
OP, all you really need to worry about is making sure condensate can drain away from the outside unit. Since that side is now the cold side, it will make some condensation that will freeze under the unit. If it piles up too much it can freeze the coils and the unit will stay in defrost mode.
OP, all you really need to worry about is making sure condensate can drain away from the outside unit. Since that side is now the cold side, it will make some condensation that will freeze under the unit. If it piles up too much it can freeze the coils and the unit will stay in defrost mode.
Posted on 11/14/26 at 8:19 am to DownshiftAndFloorIt
heat pump. your skin and sinuses will thank you. (unless you ran a humidifier)
Posted on 11/14/26 at 8:31 pm to Spankum
quote:mid-80’s I think
Man, that’s an old commercial!
Posted on 11/18/26 at 9:42 am to White Bear
After servicing pretty much everything, I'm still impressed with how much better variable speed heat pumps do in low temps than the older tech.
Posted on 11/18/26 at 2:01 pm to VandyBoysWhistler
Heat pumps are incredibly efficient and work great. However when they break, they are expensive as hell to repair.
Decades ago yes. Now they run like a Cadillac in down to negatives. I have one in my house in Minnesota and gets below 0 regularly. So much more efficient than a furnace.
quote:
Heat pumps struggle below 32 degrees.
Decades ago yes. Now they run like a Cadillac in down to negatives. I have one in my house in Minnesota and gets below 0 regularly. So much more efficient than a furnace.
This post was edited on 11/18/26 at 2:03 pm