Started By
Message

re: AFCI - Breaker keeps tripping.

Posted on 8/7/19 at 6:44 pm to
Posted by mdomingue
Lafayette, LA
Member since Nov 2010
31161 posts
Posted on 8/7/19 at 6:44 pm to
quote:

Use an ohm meter to check for a short by touching the leads to the black wire and white wire. Then black to ground. Then white to ground.


There is a reasonably good chance that white and ground are bonded at the main box so that would read like a short anyway. But black to white should give you an infinite reading if nothing is connected to the circuit. If it reads anything, verify nothing is plugged in or switched on. Any coil on the circuit may look a lot like a short,
Posted by NATidefan
Two hours North of Birmingham
Member since Dec 2008
36302 posts
Posted on 8/7/19 at 6:54 pm to
quote:


There is a reasonably good chance that white and ground are bonded at the main box so that would read like a short anyway. 


Yeah, that's true.