No.

Cracker box will be 50A, 240V.

Small machine will be 20A, 120V as they are designed for use with standard residential outlets.

One large branch circuit from your home's load center for a shop or outbuilding is normal.

Without more info, I suggest a 100A feeder to a smaller load center in your shop. Circuits for your welders, lighting & other receptacles would originate from there.
Posted by Bushmaster
19th Hole
Member since Oct 2008
39961 posts
Posted on 1/7/17 at 12:20 am to
Thanks, rev. I appreciate it. It's a 50x50 foot shop. I have all of the outlets and breakers already wired up and want to add the welders to the mix.