Pretty sure this is the column to column splice detail.



Sheet S3.14
This post was edited on 10/21/19 at 5:22 pm
Posted by BoostAddict
Member since Jun 2007
2989 posts
Posted on 10/21/19 at 6:11 pm to
Guess I'm not following what you're getting at. Yeah the columns have spices, but that doesn't means they're weak, and that elevator shaft steel is braced up like a MF'r... Sized properly, don't know, but structurally, it looks OK to me. Problem IMO is, those deck panels with no intermediate steel, were underdesigned not only for the gravity loads but lateral loads as well. The deck is supposed to create a diaphragm that transfers lateral loads from the unbraced column lines to the braced elevator shafts, which I doubt a panel size that big could do (it would possibly buckle the deck panel).