re: Attic ventilation

Posted on 8/7/19 at 8:15 am to
Posted by shell01
Marianna, FL
Member since Jul 2014
793 posts
Posted on 8/7/19 at 8:15 am to
quote:

Current residential code (2015 IRC) states the minimum attic ventilation requirements are 150/1. 


There's an exception in there, 1/300 if using ridge vents, as they are more efficient than vents NOT places at the highest point of the attic space (hot air rises...)
Posted by MarcusQuinn
Member since Aug 2005
582 posts
Posted on 8/7/19 at 7:44 pm to
I know. But I figured there was plenty of info to sort out without getting into exceptions and percentages. If it’s split high and low (40-50% high?) it can be 1/300. But if you have a continuous perforated soffit you end up with nearly 1/150 anyway to get the ratios to work.