Page 1
Page 1
Started By
Message

Want to get power line buried at my house....

Posted on 1/15/14 at 9:23 am
Posted by ShubutaMS
5682 posts
Member since Aug 2013
1434 posts
Posted on 1/15/14 at 9:23 am
Secondary, low-voltage line. Right now it is attached to house via mast. Twice in past 15 years a large limb has fallen out of neighbors tree and ripped mast, meter, box off side of house. shite sucks.

It would be about a 75ft bury to electric pole. Any idea what Entergy will want to charge me?

I also need them to upgrade the 100amp base to 200 due to moving to all electric appliances so I'm thinking they will need to upgrade service cable anyway so they might gimme a break. How does that work; do they try and make the customer incur as many expenses as they can or will they work with me seeing as burying the line will also slightly reduce their maintenance?

TiA
Posted by Truoutdorzmanfla
Louisiana
Member since Nov 2013
261 posts
Posted on 1/15/14 at 9:37 am to
I just dug my trench myself 350 ft worth. I never got an actual price the man from Entergy said 1500 to 2000!!! I said I'll do it for that. I think I spent around 900 for the pipe and the mini hoe rental. But for yours just go get a ditch witch and some pipe. It shouldn't take but half a day. And don't forget to put a string in it so they can pull the wire
Posted by Tbooux
Member since Oct 2011
1689 posts
Posted on 1/15/14 at 9:39 am to
You'll need to get a contractor to perform, entergy will only hook up the service once installed.

quote:

make the customer incur as many expenses as they can

Pretty much this. prepare thy anus
Posted by shawnlsu
Member since Nov 2011
23682 posts
Posted on 1/15/14 at 9:39 am to
You will probably have to hire an electrician to bury the conduit from the meter pan to the pole and entergy will come behind them and hook it up. They may or may not provide and pull the new cable through.
Posted by Truoutdorzmanfla
Louisiana
Member since Nov 2013
261 posts
Posted on 1/15/14 at 9:48 am to
You don't need a contractor to put the conduit just to hook up the meter base. But the conduit has to be 3 ft deep and u have to use schedule 80 above ground and schedule 40 underground and use long sweep 90s at each end. Entergy wanted to charge me for the wire at first but came back and provided the wire and pulled it and hook up for free
Posted by meauxjeaux2
watson
Member since Oct 2007
60283 posts
Posted on 1/15/14 at 9:51 am to
Here's what I did.
I rented a trencher from Home DEPOT AND BURIED MY OWN CONDUIT.
Demco came out and buried for free.
They told me they would charge me to to bury underground shielded wire.
Posted by Stexas
SWLA
Member since May 2013
7140 posts
Posted on 1/15/14 at 9:52 am to
quote:

You don't need a contractor to put the conduit just to hook up the meter base. But the conduit has to be 3 ft deep and u have to use schedule 80 above ground and schedule 40 underground and use long sweep 90s at each end. Entergy wanted to charge me for the wire at first but came back and provided the wire and pulled it and hook up for free


x2 - They're encouraging this so they can restore power more quickly in storm situations.
Posted by Truoutdorzmanfla
Louisiana
Member since Nov 2013
261 posts
Posted on 1/15/14 at 9:54 am to
quote:

x2 - They're encouraging this so they can restore power more quickly in storm situations.



That's exactly what they told me
Posted by warr09
Georgia by way of Baton Rouge
Member since Jan 2013
800 posts
Posted on 1/15/14 at 9:55 am to
Yeah. What he said.


Just dig the trench yourself. Rent a trencher or a mini ex and run the conduit yourself. Pretty simple actually. May want to wait until they disconnect the incoming before jacking around connecting the new conduit to the meter can. Stub up at the pole and like the other poster said, put a pull string in. A 75' run should be pretty cheap since your looking at 8 sticks on the ground run with turnups and likely 2-3 sticks up your house and the pole. Check with Entergy regarding if you need to stub up at the base of the pole. Or run up the pole and add a weatherhead.
Posted by ShubutaMS
5682 posts
Member since Aug 2013
1434 posts
Posted on 1/15/14 at 10:32 am to
Thanks for the replies. Gives me a better idea at what I'm in for.

Heard conflicting info from people about being able to dig own ditch but really hope Entergy will let me do so. Same for conduit. If they want a sparky to do it I'm hoping I can find one that will let me do the labor and just come out to give it a looksee and hookup meter base.
I'm in a MS county with very little regulation so maybe that will help.

Like most of the OB I'm pretty capable with this kind of stuff and don't foresee me having any trouble with the work. If I'm out as much as a grand I will be okay with it. 500 would be better tho.

Scheduled to have an Entergy engineer come out later this week and tell me what it is.


quote:

350 ft...1500 to 2000

Sounds reasonable.

quote:

prepare thy anus

Going to act like I'm unsure whether or not I want to bury it and hope that the engineer will meet me in middle to reduce their maintenance.

quote:

conduit has to be 3 ft deep and u have to use schedule 80 above ground and schedule 40 underground and use long sweep 90s at each end.

Entergy has detailed illustrations of pretty much just what you said on their site.

quote:

x2 - They're encouraging this so they can restore power more quickly in storm situations.
:fingercrossed:

Thanks again, will update after he comes out if anyone cares.
Posted by Truoutdorzmanfla
Louisiana
Member since Nov 2013
261 posts
Posted on 1/15/14 at 10:42 am to
Kelps us posted on what they say I'm curious Like I said I just did mine
Posted by warr09
Georgia by way of Baton Rouge
Member since Jan 2013
800 posts
Posted on 1/16/14 at 10:19 am to
Stay below the frost line. If your jurisdiction doesn't require an electrical permit to be pulled, you should be good. Your likely still good if Entergy makes all the connections. I have contacts all over the southeast US if you do need to pull a permit.
Posted by warr09
Georgia by way of Baton Rouge
Member since Jan 2013
800 posts
Posted on 1/16/14 at 10:22 am to
Forgot. Call the Louisiana or Mississippi One Call number depending on where you live to covee your rear.
Posted by MWP
Kingwood, TX via Monroe, LA
Member since Jul 2013
11250 posts
Posted on 1/16/14 at 10:27 am to
quote:

Forgot. Call the Louisiana or Mississippi One Call number depending on where you live to covee your rear.


I am glad someone finally posted this. Do this before you dig please if doing this on your own. Last thing you need to hit is an unmarked sewer/electric/cable line or heaven forbid a pipeline.
first pageprev pagePage 1 of 1Next pagelast page
refresh

Back to top
logoFollow TigerDroppings for LSU Football News
Follow us on X, Facebook and Instagram to get the latest updates on LSU Football and Recruiting.

FacebookXInstagram