Cold air returns vs hot air

Posted on 8/2/17 at 10:42 am
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 10:42 am
I know that two of the hot air returns in my apartment are supposed to get filters because they have the easy access sliders. The other cold air return downstairs, is screwed to the wall, no easy access sliders, and doesn't get a filter. Can an HVAC guy explain the reasoning behind this?

I pretty sure hot air returns are near the ceiling, and cold air is near the floor.
Posted by goofball
Member since Mar 2015
17356 posts
Posted on 8/2/17 at 10:44 am to
I prefer cold air this time of year.
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 10:46 am to
I didn't know they were broken out into "hot air" and "cold air". If a return doesn't have a filter, then the filter is somewhere internal, or the design is fubar. ETA: Multiple returns suggests good design. Most houses are starved of returns.
This post was edited on 8/2/17 at 10:48 am
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 10:49 am to
Hot air is near the ceiling to pull hot air out of the room since heat rises. Cold air is near the floor to pull cold air when the space needs to be heated.
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 10:50 am to
It's a 4 story unit. One hot air on the 4th floor, one on the 1st, cold air on the 2nd.
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 10:50 am to
I understand what you're getting at, but since you're gonna be wrong half the time, I wasn't aware it was done for that reason.
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 10:51 am to
What do you mean?
Posted by Sao
East Texas Piney Woods
Member since Jun 2009
68469 posts
Posted on 8/2/17 at 10:53 am to

My guess is the handler/furnace is on the 2nd, yes?
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 10:54 am to
You're not always cooling or heating, and with air mixing, I'm not sure it matters. Especially with a single return, I always thought it was about convenience.
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 11:00 am to
quote:

It's a 4 story unit. One hot air on the 4th floor, one on the 1st, cold air on the 2nd.


OK, ignore me except the part about all returns are filtered unless something is seriously screwed up.
Posted by TigerstuckinMS
Member since Nov 2005
33687 posts
Posted on 8/2/17 at 11:01 am to
Air returns used only for heating don't NECESSARILY need a filter.

The main reason for a filter on an AC system isn't to clean the air for you. It's to provide clean air for the evaporator coils. AC systems don't cool by just dropping the temperature. Most of the heat in hot air is tied up in the moisture in the air, so AC systems are designed to dehumidify the air and in the process provide chilled air. They do this by condensing the moisture on the evaporator coils. This water collects on the coils and if the air blowing across them is dusty, the dust gets deposited in the water on the coils. When the coils are deactivated and the water evaporates, it leaves a layer of dust behind. Repeat this over and over, and you make a layer of concrete like material on the coils that greatly inhibits their ability to properly function. The filter in an AC system is there to prevent this. A byproduct is that it also makes the air cleaner for the people in the space.

Heating air doesn't involve condensation. It just heats the air. So, even if you're heating the air with the condensing coils in a heat pump, it's not as critical to filter the air (though still a REALLY good idea) as it is during the cooling cycle because there's no water to make the slurry to make the concrete on the coils.

If you have completely separate heating and cooling, using a furnace or electric coil for heat, then there are no refrigeration coils to worry about in the heating cycle, and filtering is even less necessary from a "protect the equipment" standpoint, though there is going to be an increased fire risk in electric heaters.
This post was edited on 8/2/17 at 11:05 am
Posted by doubleb
Baton Rouge
Member since Aug 2006
43078 posts
Posted on 8/2/17 at 11:01 am to
If you have one blower then the RAGs are common to one system and the RA is being drawn through each RAG all the time.

If two RAGs have a filter and one does not then you must have a filter at the unit to protect the fan and the cool. If you don't it's not set up properly.
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 11:01 am to
Nope ,4th floor, in the crawl space. It's a shittastic design.

4 story townhome so the air conditioner is outside on the ground level, the handler is on the 4th floor.
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 11:04 am to
quote:

If you have completely separate heating and cooling


Mind blown. Is that really a thing?
Posted by Sao
East Texas Piney Woods
Member since Jun 2009
68469 posts
Posted on 8/2/17 at 11:06 am to
quote:

4 story townhome so the air conditioner is outside on the ground level, the handler is on the 4th floor.


That's a really long copper run.

But if you feel like you need a filter grill on the 2nd, just change it out. It's simple work really. Shouldn't affect flow much if you avoid getting a really dense/expensive filter (overkill there)
Posted by TigerstuckinMS
Member since Nov 2005
33687 posts
Posted on 8/2/17 at 11:08 am to
quote:

Mind blown. Is that really a thing?

Yeah. Think places that might have a furnace and a dedicated straight AC instead of a heat pump. Boston. Places like that get bitterly cold in the winter and a heat pump is not the best choice to maintain a comfortable indoor temperature when the outside air temp drops very low. So, some other source of heat is more effective and efficient in those conditions. It also gets blisteringly hot and muggy in the summer, so some cooling is wanted, too, so you'll still see an AC, it will just be a straight AC system, not a heat pump.
This post was edited on 8/2/17 at 11:15 am
Posted by Spock's Eyebrow
Member since May 2012
12300 posts
Posted on 8/2/17 at 11:11 am to
Fascinating.
Posted by themasterpater
I travel
Member since Sep 2014
1358 posts
Posted on 8/2/17 at 11:11 am to
Yeah I was just curious because the landlord said not to put a filter on it because "it's an intake vent". In and of itself that statement makes no sense because the other intake vents get them. It does seem like it's designed not to receive a filter since the whole grill is screwed down, as opposed to the others where they have slider tabs to easily replace filters.

I do realize that filters primary pupose is to limit build up of dust on the coils and to protect the unit. I'm just not sure why one intake vent seems designed not to get a filter.
Posted by TigerstuckinMS
Member since Nov 2005
33687 posts
Posted on 8/2/17 at 11:16 am to
quote:

Fascinating.

Not really. It paid the bills for a while, though.
Posted by Sao
East Texas Piney Woods
Member since Jun 2009
68469 posts
Posted on 8/2/17 at 11:20 am to
quote:

I do realize that filters primary pupose is to limit build up of dust on the coils and to protect the unit. I'm just not sure why one intake vent seems designed not to get a filter.


You may have a filter at the unit as well. If horizontal, at the plenum and coil. If upright, at the base/platform. Take a look