re: Natural Gas Line Testing and Use

Posted on 8/13/19 at 11:26 am to
Posted by Ashtray
La
Member since Apr 2017
157 posts
Posted on 8/13/19 at 11:26 am to
I have nearly the same setup, you wont have any issues with pressure. If anything you may have issues with not enough volume to supply your generator if your line is a long run from your house gas meter. Most of those gen set conversion kits have a table showing pipe size for length of run to the generator. Mine was just over the spec where they recommend 3/4 inch pipe to deliver the volume, but the 1/2 line runs my 5KW just fine on full load