quote:

they said it doesn't put off enough BTU for generator.


I’d highly recommend you run one that support a generator
Posted by lsujunky
Down By The River
Member since Jun 2011
2273 posts
Posted on 3/4/21 at 1:34 pm to
quote:

I’d highly recommend you run one that support a generator


If he is just tying into his original house line he will not have enough pressure for a generator. Regular house pressure is like 7" water column a generator needs 11" water column. So he would need a whole different line coming from the meter with a separate 11" water column regulator.