Posted on 8/10/22 at 3:58 pm to
quote:

My electrician placed a volt meter on the terminals leading into my breaker panel. Leg 1 showed 135V, Leg 2: 129V It would continuous cycle from 119V to 135V when a high load appliance was run


The problem with this is the electrician measured the voltage at points after the meter base. These voltage fluctuations could be caused by loose connections within the meter base which is very common, and not Entergy’s responsibility. Their responsibility for wiring stops at the crimped connections at the top of the service entrance weatherhead assuming you have above ground electrical drop.