Posted on 2/9/23 at 8:23 pm
Posted on 2/9/23 at 8:23 pm
Does anyone have an idea what may be wrong with my AC? The inside and outside units will run, but no air is coming out of the vents. Nothing is frozen up outside. Fan motor??
Update: it was the coil, had a leak and was freezing up.
Update: it was the coil, had a leak and was freezing up.
This post was edited on 2/10/23 at 11:26 am
Posted on 2/9/23 at 8:25 pm to Bucktail1
Well you said that inside unit is running.
That IS the blower. You may have an X 13 motor, that is turning slowly, stopping and confusing spin backward then forward, etc.
That will be a module, piggybacked on the blower motor
That IS the blower. You may have an X 13 motor, that is turning slowly, stopping and confusing spin backward then forward, etc.
That will be a module, piggybacked on the blower motor
This post was edited on 2/9/23 at 8:28 pm
Posted on 2/9/23 at 8:29 pm to Bucktail1
You have a Freon issue, maybe a leak.
Posted on 2/9/23 at 8:32 pm to EF Hutton
Yeah, the unit in attic is running but no air coming out of the vents.
Posted on 2/9/23 at 8:34 pm to EF Hutton
Ok, that sounds like something that I can’t handle. I guess I’ll call a service person tomorrow
Posted on 2/9/23 at 8:34 pm to Bucktail1
Normally I’d say its frozen and the air can’t get thru ice, in which case it could be a freon issue, but u said not froze
Posted on 2/9/23 at 8:34 pm to EF Hutton
Not frozen from what I can see. I checked lines outside and they look fine
Posted on 2/9/23 at 8:36 pm to Bucktail1
Too far. Ok, probably a motor module.
Brand ? Age ?
Brand ? Age ?
Posted on 2/9/23 at 8:38 pm to EF Hutton
Not sure of the brand, I just came down out of the attic, but it’s almost 10 yrs old
Posted on 2/9/23 at 8:39 pm to Bucktail1
Carrier / bryant has an inexpensive motor that replaces the factory x13 mtr.
Works well.
Works well.
Posted on 2/9/23 at 8:42 pm to Bucktail1
Slightly pull one side of air filter out of grille, then let go. See if it gets sucked back in, or throw layer of toilet paper on grille, see if vacuum holds the paper .
Posted on 2/9/23 at 9:40 pm to Bucktail1
When you say that it runs, is the fan spinning outside?
I’m thinking it’sa capacitor
I’m thinking it’sa capacitor
This post was edited on 2/9/23 at 9:45 pm
Posted on 2/9/23 at 9:46 pm to hophead
He said the inside unit was running. My guess is he is hearing something, but it’s not spinning 100%.
OR
It is frozen, in which case his evap coil fins are plugged, or low on freon.
OR
It is frozen, in which case his evap coil fins are plugged, or low on freon.
Posted on 2/9/23 at 9:54 pm to EF Hutton
Probably low on refrigerant and coil is frozen
Or air filter is very dirty. Check your filter first
Or air filter is very dirty. Check your filter first
Posted on 2/9/23 at 10:15 pm to EF Hutton
quote:
He said the inside unit was running. My guess is he is hearing something, but it’s not spinning 100%.
It sounds like the squirrel cage on the blower in the attic either broke or the set screw holding it onto the motor shaft loosened up somehow. But if that happened it would cause the lines to freeze up do to lack of airflow across evaporator coil. That is providing the system is charged up to the required amount of Freon
Posted on 2/10/23 at 7:52 am to Miketheseventh
1) The air filter was changed about 2 weeks ago so it’s clean . 2) the outside fan is spinning 3) the inside unit is sucking air through the intake