Started By
Message

re: Power Home HVAC with Portable Gen (Part 2: MicroAir 368 Review)

Posted on 7/19/22 at 3:39 pm to
Posted by DVinBR
Member since Jan 2013
13150 posts
Posted on 7/19/22 at 3:39 pm to
I have an oscilloscope, a current clamp that works with it, and a high voltage differential probe

I'll post some pictures of what a 3 Ton compressor start looks like electrically when i get some time
Posted by DVinBR
Member since Jan 2013
13150 posts
Posted on 8/21/22 at 10:56 am to
BEFORE INSTALLING HYPER ENGINEERING SOFT STARTER

1. yellow: voltage across start winding, blue: current into the common terminal (10mV/A)


2. more detailed voltage across the start winding


3. yellow: voltage across run winding, blue: current into common terminal (10mV/A)


AFTER INSTALLING HYPER ENGINEERING SOFT STARTER

1. voltage across run winding during start


2. more detail voltage across run winding during initial start


3. even more detail


4. voltage across run winding right before full voltage is applied


5. voltage across run winding after start


Clearly you can see a TRIAC firing on the start with the soft starter, and it's not a near 0 ramp, it begins with about 1/2 of a cycle and ramps up very fast staring after only 15 cycles or so


This post was edited on 8/21/22 at 11:03 am