Started By
Message
locked post

Standby generator just shut down

Posted on 8/29/12 at 4:21 am
Posted by Benchwarmer
Member since Feb 2004
4963 posts
Posted on 8/29/12 at 4:21 am
How does that happen?
Posted by lsu480
Downtown Scottsdale
Member since Oct 2007
92876 posts
Posted on 8/29/12 at 4:22 am to
Turn on the original one if the standby isn't working.
Posted by papasmurf1269
Hells Pass
Member since Apr 2005
20893 posts
Posted on 8/29/12 at 4:25 am to
Check oil.May be low pressure shutdown.
Posted by fishfighter
RIP
Member since Apr 2008
40026 posts
Posted on 8/29/12 at 4:33 am to
quote:

Check oil.May be low pressure shutdown.


This or no fuel.

Or, if you have a Auto transfer switch and power came back on, it should shut down.
This post was edited on 8/29/12 at 4:35 am
Posted by Benchwarmer
Member since Feb 2004
4963 posts
Posted on 8/29/12 at 4:48 am to
can i use sae 30 or does it have to be synthetic. wife will not be pleased
This post was edited on 8/29/12 at 4:50 am
Posted by LaBornNRaised
Loomis blows
Member since Feb 2011
11004 posts
Posted on 8/29/12 at 4:58 am to
Everybody at my house was bitching about how loud they were... I can only imagine the bitching if they shut off.



Good luck ....
Posted by fishfighter
RIP
Member since Apr 2008
40026 posts
Posted on 8/29/12 at 5:09 am to
quote:

can i use sae 30 or does it have to be synthetic. wife will not be pleased



Yes, but not the best to mix both together. Change the oil the first chance you get though.

Oil change at every 50 running hours.
This post was edited on 8/29/12 at 5:10 am
Posted by XxxSpooky1
A place in SE La
Member since Sep 2007
5145 posts
Posted on 8/29/12 at 5:46 am to
(no message)
This post was edited on 1/15/13 at 10:59 am
Posted by Benchwarmer
Member since Feb 2004
4963 posts
Posted on 8/29/12 at 7:18 am to
Fault 3 = Low Voltage, oil is full. tried just restaring it like my laptop. It ran for 60 seconds and died again. manual says call for service. other that, any ideas.
Posted by fishfighter
RIP
Member since Apr 2008
40026 posts
Posted on 8/29/12 at 7:21 am to
Sounds like it is not running up to speed. Could be that the carb high speed jet is pluging up or you overloading it.
Posted by TexasVines
Member since Nov 2010
10 posts
Posted on 8/29/12 at 7:28 am to
LINK /

Low Voltage (Generator, FC_3)

This fault is indicated by fault code FC_3 and three blinks on the LED indicator. This condition is caused by a restriction in the fuel flow, a broken or disconnected signal lead, a failed alternator winding, the control panel circuit breaker is open, or the generator is overloaded.
Posted by DaphneTigah
Flying under the radar.
Member since Dec 2007
4980 posts
Posted on 8/29/12 at 7:29 am to
What is the Make/Model of the generator?

Also: What is the fuel type?
Posted by DaphneTigah
Flying under the radar.
Member since Dec 2007
4980 posts
Posted on 8/29/12 at 7:30 am to
quote:

or the generator is overloaded.




hmmm
Posted by skidry
Member since Jul 2009
3261 posts
Posted on 8/29/12 at 7:35 am to
If you have 2 AC units try running one at a time or none at all.
Posted by DaphneTigah
Flying under the radar.
Member since Dec 2007
4980 posts
Posted on 8/29/12 at 7:36 am to
If your generator is feeding your entire house, you should try going to your subpanel and opening some of the larger breakers (i.e, A/C, Dryer, Stove, Hot Water Heater) and then try starting it. Obviously if it runs after doing this than the unit would have been overloaded.
Posted by Benchwarmer
Member since Feb 2004
4963 posts
Posted on 8/29/12 at 7:36 am to
not overload cuz most of the house was shutdown when it happned. tried again with no a/c's on. 25 seconds and died. It's a B&S 15kw thats 4years old (naturl gas) and never failed before.
This post was edited on 8/29/12 at 8:09 am
Posted by Quidam65
Q Continuum
Member since Jun 2010
19307 posts
Posted on 8/29/12 at 7:37 am to
If you're still not having luck call our TD generator expert MeauxJeaux2.

Check this thread. Contact info on first page.

LINK
This post was edited on 8/29/12 at 7:38 am
Posted by DaphneTigah
Flying under the radar.
Member since Dec 2007
4980 posts
Posted on 8/29/12 at 7:38 am to
What about the Hot Water Heater?
Posted by DownshiftAndFloorIt
Here
Member since Jan 2011
66763 posts
Posted on 8/29/12 at 7:39 am to
Turn off the whole house and try it.
Posted by Benchwarmer
Member since Feb 2004
4963 posts
Posted on 8/29/12 at 8:19 am to
Thanks Qui, I have sent an email and anxiously await his guidance.
first pageprev pagePage 1 of 2Next pagelast page

Back to top
logoFollow TigerDroppings for LSU Football News
Follow us on Twitter, Facebook and Instagram to get the latest updates on LSU Football and Recruiting.

FacebookTwitterInstagram