re: New Construction HVAC question

Posted on 11/1/18 at 9:23 pm to
Posted by cajuncarguy
On the road...Again!
Member since Jun 2013
3135 posts
Posted on 11/1/18 at 9:23 pm to
quote:

I would not trust any "rule of thumb" he needs a accurate heat load calculation for the house, in South LA too large of a unit is worse than too small.


Agree. If you have too much AC your compressor will not run long enough to dehumidify. There are software programs that can calculate the load based on SF, orientation, windows, insulation, people in house, etc. Your builder should be able to help or others on here.
Posted by Joshkdixon
Baton Rouge
Member since Feb 2014
79 posts
Posted on 11/1/18 at 9:26 pm to
Thanks. Owner of hvac says he did manual J calculation, which I specifically asked him. I trust that he did. I'm leaning towards 2 separate systems.