Open Canvas: Hazardous Work Environment
Posted on 11/5/12 at 2:20 pm
Posted on 11/5/12 at 2:20 pm
There are supposed to be 10 hazards in this image... I have a feeling there are a lot more.
1. The Hair Dryer
What else can y'all find?
1. The Hair Dryer
What else can y'all find?
Posted on 11/5/12 at 2:23 pm to yurintroubl
Well after reviewing the picture I did notice the broom which leads me to think this might be the future job site of one Gene Chizik,
Posted on 11/5/12 at 2:33 pm to yurintroubl
The spot on the floor under the eye wash station. The cart is dirty.
Posted on 11/5/12 at 2:55 pm to Rattlehead
quote:
Rattlehead
And since somebody has already pointed out the wet floor in that area... Ruh roh.
Posted on 11/5/12 at 3:05 pm to yurintroubl
Just off the top of my head...
1. Tongue guard greater than 1/4" from grinding wheel (x2).
2. Access to Eyewash blocked
3. Electrical switch (feeding pedestal grinder) in close proximity to eyewash/shower. Not sure if there is wiring behind the metal receptacle plate as well.
4. Grinder fed by flexible cord used as permenant installation (should be hard wire in flex conduit).
5. Hard to tell the condition of the hammer, but it looks like the head may be damaged.
6. Danger/warning/caution signs for same hazard (conflicting message).
7. Hard to tell with eyewash, but if it is being fed by a single line, does it meet the requirements for temperature.
1. Tongue guard greater than 1/4" from grinding wheel (x2).
2. Access to Eyewash blocked
3. Electrical switch (feeding pedestal grinder) in close proximity to eyewash/shower. Not sure if there is wiring behind the metal receptacle plate as well.
4. Grinder fed by flexible cord used as permenant installation (should be hard wire in flex conduit).
5. Hard to tell the condition of the hammer, but it looks like the head may be damaged.
6. Danger/warning/caution signs for same hazard (conflicting message).
7. Hard to tell with eyewash, but if it is being fed by a single line, does it meet the requirements for temperature.
Posted on 11/5/12 at 3:06 pm to madmaxvol
quote:
Just off the top of my head...
1. Tongue guard greater than 1/4" from grinding wheel (x2).
2. Access to Eyewash blocked
3. Electrical switch (feeding pedestal grinder) in close proximity to eyewash/shower. Not sure if there is wiring behind the metal receptacle plate as well.
4. Grinder fed by flexible cord used as permenant installation (should be hard wire in flex conduit).
5. Hard to tell the condition of the hammer, but it looks like the head may be damaged.
6. Danger/warning/caution signs for same hazard (conflicting message).
7. Hard to tell with eyewash, but if it is being fed by a single line, does it meet the requirements for temperature.
8. Gremlin eating late near water
9. Hair Dryer
Posted on 11/5/12 at 3:31 pm to yurintroubl
quote:
8. Gremlin eating late near water
That's a mogwai.
Posted on 11/5/12 at 3:34 pm to Catahoula
You dropped a bag of glass on my baby!!
Posted on 11/5/12 at 3:47 pm to yurintroubl
quote:
You dropped a bag of glass on my baby!!
My apologies madam. I missed your post. We're working too fast.
ETA...pick it up from Spurticus. I have another idea.
This post was edited on 11/5/12 at 3:48 pm
Posted on 11/5/12 at 3:51 pm to ugasickem
Appologizes to the guys above my post. Looks like
I was working on one, and posted before I saw
those.
I was working on one, and posted before I saw
those.
Posted on 11/5/12 at 4:03 pm to madmaxvol
quote:
Just off the top of my head...
1. Tongue guard greater than 1/4" from grinding wheel (x2).
2. Access to Eyewash blocked
3. Electrical switch (feeding pedestal grinder) in close proximity to eyewash/shower. Not sure if there is wiring behind the metal receptacle plate as well.
4. Grinder fed by flexible cord used as permenant installation (should be hard wire in flex conduit).
5. Hard to tell the condition of the hammer, but it looks like the head may be damaged.
6. Danger/warning/caution signs for same hazard (conflicting message).
7. Hard to tell with eyewash, but if it is being fed by a single line, does it meet the requirements for temperature.
how's about all kinds of shite over the "keep clear" line?
also, I'd imagine the signs being obscured is a hazard.
and there's a goddamn maguai up in there.
Popular
Back to top
Follow TigerDroppings for LSU Football News