re: Federal agency confirms fire has broken out on blown-out gas well

quote:

Well likely will have killed itself before 25 days. I'm looking at their sDOCD and their Uncontrolled blowout on their Worst Case Discharge is 200 bbls of condensate/ day. I also bet it was the accumulator that got them into this situation not the BOP's failing.


I read that they shot the zone and the drilling fluids went south. Guess they didnt have enough bromide on hand.


TH03
Notre Dame Fan
Member since Dec 2008
103473 posts

re: Federal agency confirms fire has broken out on blown-out gas well
sorry, 3rd bypass. 3 of the applications I saw were for the same bypass, just revised permits


Replies (0)
Replies (0)
TH03
Notre Dame Fan
Member since Dec 2008
103473 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

I'm looking at their sDOCD and their Uncontrolled blowout on their Worst Case Discharge is 200 bbls of condensate/ day.


yea I saw that yesterday


Replies (0)
Replies (0)
11Tiger
LSU Fan
Really Close
Member since May 2007
663 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

Well likely will have killed itself before 25 days.


I hope so. Hurricane could possibly be in the gulf next week and slow down the progress of drilling the relief well.


Replies (0)
Replies (0)
Corkfather
LSU Fan
Tyler, TX
Member since Sep 2007
18696 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

I read that they shot the zone and the drilling fluids went south. Guess they didnt have enough bromide on hand.


Were they still drilling or had they moved to completion? There should have been enough barite to keep the mud heavy enough to control the kick.

I'd love to know circulating pressure when this went down.


TH03
Notre Dame Fan
Member since Dec 2008
103473 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

The blowout is A-3 so that indicates at least 3 drilled. One may have been exploratory but probably not. I'm not sure if the other two are completed, Shut-in, P/Ad or whatever.


I just searched production for this lease, and it's only showing 1 producing well which appears to be this one.

last 2 months of production

11/2012: 228,139 MCF, 1,323 BBL (condensate)

12/2012: 41,311 MCF, 322 BBL (condensate)


Replies (0)
Replies (0)
Sid in Lakeshore
LSU Fan
Member since Oct 2008
24932 posts

re: Federal agency confirms fire has broken out on blown-out gas well
They were in completion mode.


Replies (0)
Replies (0)
Javzz
Maryland Fan
Member since Jan 2006
1384 posts

re: Federal agency confirms fire has broken out on blown-out gas well
Few people in this thread have mentioned the kick was after shooting the perfs


Replies (0)
Replies (0)
TH03
Notre Dame Fan
Member since Dec 2008
103473 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

Were they still drilling or had they moved to completion?


permit just shows a spud date of 6/26/2013, but hasn't been updated with geological information or casing specs so I'm not sure


Replies (0)
Replies (0)
Placebeaux
LSU Fan
One man's LOL is another man's WTF
Member since Jun 2008
27957 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

they still drilling or had they moved to completion


if they shooting perfs, they in completion


Corkfather
LSU Fan
Tyler, TX
Member since Sep 2007
18696 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

if they shooting perfs, they in completion


No shit, I asked that before someone mentioned it happened after they shot.

Was wireline still downhole or had they already started pumping?


polizei11
LSU Fan
Lafayette
Member since May 2009
1012 posts

re: Federal agency confirms fire has broken out on blown-out gas well
Info on the Field and Wells

Area: South Timbalier
Block: 220

3 Slots on Braced Caisson. Structure Name: "A"
1 Slot Used: A-3
Cumulative Production from Structure: 332 MBO, 37 BCF, 372 MBW from 8/1998-12/2012.
Image: http://www.osf-llc.com/images/Turnkeys/TK003_01.jpg


Water Depth: 158'

Well A-1: Currently, TA'd. Produced 162 MBO, 15 BCF, 243 MBW from 8/1998-7/2001 all in 11,100' Sand.

Well A-2: Dry Hole drilled in 4-5/1998.

Well A-3: Original well was dry hole.
Well A-3 ST1: Well bypassed twice. BP02 produced 170 MBO, 19 BCF, 20 MBW from 10/2006-12/2012 all in 11500' Sand. Max reported test I see is 11.1 MMCFD. Pretty high initial BHP at 9150 psia.
This post was edited on 7/24 at 2:28 pm


Replies (0)
Replies (0)
polizei11
LSU Fan
Lafayette
Member since May 2009
1012 posts

re: Federal agency confirms fire has broken out on blown-out gas well
They were shooting with TCP guns.


TchoupitoulasTiger
LSU Fan
NOLA
Member since May 2011
102 posts

re: Federal agency confirms fire has broken out on blown-out gas well
Yea this was a TCP job. I wonder what they had in the hole from a test tool/ BHA standpoint. Anybody know if they had POTV/MRCV, IRIS/IRDV, or an OMNI valve in the hole?



barry
Cincinnati Fan
Location, Location, Location
Member since Aug 2006
40606 posts

re: Federal agency confirms fire has broken out on blown-out gas well
Well the sales meeting at Walter should be a riot next week.


Placebeaux
LSU Fan
One man's LOL is another man's WTF
Member since Jun 2008
27957 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

Well the sales meeting at Walter should be a riot next week.


who was the old man over most of Walters stuff out there?


Replies (0)
Replies (0)
Corkfather
LSU Fan
Tyler, TX
Member since Sep 2007
18696 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

TCP


If they were using a CT unit couldn't they have just bullheaded and killed the well when it kicked?

Is there any info as to what they did to control the well?


beaver
USA Fan
The 755 Club
Member since Sep 2009
43944 posts

re: Federal agency confirms fire has broken out on blown-out gas well
SIAP



Replies (0)
Replies (0)
polizei11
LSU Fan
Lafayette
Member since May 2009
1012 posts

re: Federal agency confirms fire has broken out on blown-out gas well
They weren't using a CT unit. They were using a completion string. One of the main reasons to use TCP guns is to perforate underbalanced. The well WILL start producing if you are truly underbalanced. Using the TCP method of perforating allows you to conduct a drill stem test immediately after perforating.

Probably not much info about what they did to control the kick so that's why we are speculating.


lsuroadie
LSU Fan
South LA
Member since Oct 2007
6634 posts

re: Federal agency confirms fire has broken out on blown-out gas well
quote:

frick a BOP

they never work
they work everyday brother...hundreds of times round the world, every single day


Replies (0)