Started By
Message

re: What is a reasonable quote for a new AC unit for 1800 sq ft house?

Posted on 4/26/24 at 8:51 pm to
Posted by BeerMoney
Baton Rouge
Member since Jul 2012
8388 posts
Posted on 4/26/24 at 8:51 pm to
Specifics probably matter. What exactly are they proposing in terms of systems.
Posted by LoneStar23
USA
Member since Aug 2019
5210 posts
Posted on 4/26/24 at 8:59 pm to
quote:

Specifics probably matter. What exactly are they proposing in terms of systems.


quote:

INCLUDES
Refrigerant recovery and disposal per EPA Guidelines. Disconnect existing ducts from supply plenum. Removal and disposal of existing supply plenum, air handler and heat pump condenser. Area preparation for new system installation. Flush refrigerant line set with NITROGEN to remove R-22 refrigerant residue.
Installation of new galvanized metal drain pan with safety float switch.
Installation of metal heater stands or foam blocks (if applicable).
Installation of new air handler with Multi Speed ECM blower.
Installation of metal supply plenum with duct connections with dampers. Seal all connections (return, air handler, supply plenum and duct connections with mastic material. Connect all flex ducts to supply plenum.
Installation of 15.2 SEER-2 heat pump condenser with compressor sound blanket, pressure switches and
voltage monitor. Replacement of electrical whip to condenser. All electrical connections (high and low voltage). All copper line set connections including liquid line filter drier.
first pageprev pagePage 1 of 1Next pagelast page
refresh

Back to top
logoFollow TigerDroppings for LSU Football News
Follow us on Twitter, Facebook and Instagram to get the latest updates on LSU Football and Recruiting.

FacebookTwitterInstagram